The pre-assembled building
from dealer Clegg Co. at 1444 S. Kelly Rd., Schenectady, NY 12306,
518-864-5396 and 518-864-5474 fx, shall be steel construction. Dimensions to be _____ wide x _____ long and 96" in height.
Frame: Framing will be comprised of 2" x 2" x .120" structural tube, ASTM A5000 grade B. All seams to be MIG welded. Any and all exposed seams will be
ground flat and smooth.
Base/Floor: Building to typically be constructed on a 4" galv. structural tube frame. Floor assembly to be 2" thick comprised of galv. steel underside,
insulation and 1/8" aluminum treadplate finished floor.
Wall Panels: All wall panels will consist of 14 gauge exterior, 2" of R-16 insulation and a 16 gauge inside face. All panels will be galvanized and will be MIG
welded into place.
Ceiling: Interior ceiling will be foam core panel system providing smooth flat interior. Constructed from 24 GA prefinished white with expanded polystyrene core.
Roof: Will be constructed using 20 GA, G-90 interlocking pan sections. Sections to be factory coated with industrial quality polyester white paint. Sections to be
3" high with varying widths able to support minimum of 50 PSF live load. Roof drains into full-perimeter gutter system.
Finish: All exterior surfaces to be smooth and flat with no visible blemishes. All surfaces to be painted using an epoxy/urethane prime to paint system designed to
withstand salt spray and freeze thaw testing.
Windows: Fixed windows will be 3/16" tempered safety glass. All sliding and cashier windows will be ½" insulated tempered safety glass. All window frames
will be anodized aluminum and fastened to building with no exposed fasteners. All moving windows will be supplied with locking device.
Doors: Standard door to be sliding type. The door to be top hung style using an aluminum overhead track and rollers. Swing door is to be aluminum commercial grade
with 3 hinges and closure arm. Both style doors will be supplied with mortise locks and removable cylinders.
Electrical: All electrical will be wired according to N.E.C. Standards. The load center will be a General Electric 125 Amp 120/240 volt unit with 4 to 8 open
circuits. All wiring will be within surface mounted EMT conduit lines. Included will be a GFCI duplex receptacle with tester.
Lighting: Lighting will be a twin fluorescent light with tube covers. Size and quantity will depend upon the booth size.
Heat: Heating will be wall mounted electric with fan forced operation, 1500w/5120 BTU and thermostat in an enamel coated 20 gauge steel cabinet.